Does not burn

Durability

High heat retention capacity

No shrinkage

Resistant to rodents and mold

Volume and shape stability

Documents

TU U V.2.7-23.9-35492904-006:2024

Thermal and acoustic insulation boards made of mineral wool

Product Description and Scope of Application

THERMOWOOL LIGHT are non-combustible, hydrophobized thermal and acoustic insulation boards made of mineral wool based on basalt group rocks.

THERMOWOOL LIGHT EXTRA 30 boards are designed for thermal and acoustic insulation of building structures in residential buildings and industrial facilities where the insulation does not bear external loads (attics, attic floors, floors with insulation laid between joists; frame partitions).


Transportation and Storage

Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.

Packaging Information

Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material ensures reliable and durable packaging of the boards, their protection during loading and unloading operations, transportation and storage.

Application Instructions

In accordance with SWEETONDALE Installation Instructions

Main physical and mechanical characteristics:

Parameter

THERMOWOOL LIGHT EXTRA 30

THERMOWOOL LIGHT OPTIMA 35

Test Method

Density, kg/m3

30±5

35±5

DSTU B V.2.7-38

Declared thermal conductivity at 10°C, W/(m·K), not more than

0,038

0,036

DSTU B EN 12667
EN 12939

Thermal conductivity, W/m*K
λA
λB

0.041
0.042

0.039
0.041

DSTU B V.2.7-182

Compressive stress at 10% linear deformation, kPa, not less than

0,5

0,5

DSTU EN 826

Long-term water absorption, kg/m2, not more than

3

3

EN 12087

Short-term water absorption, kg/m2, not more than

1

1

EN 1609

Reaction to fire

A1

A1

DSTU EN 13501-1

Combustibility class

NG

NG

DBN V.1.1-7

Effective service life, years, not less than

50

50

DSTU B V.2.7-182

 

Geometric parameters:

Parameter

Unit of measurement

THERMOWOOL LIGHT EXTRA 30

THERMOWOOL LIGHT OPTIMA 35

Test Method

Length

mm

1200

1200

DSTU EN 822

Width

mm

600

600

DSTU EN 822

Thickness (in 10 mm increments)

mm

50-100, 150-200

50-100, 130-200

DSTU EN 823

Tolerance limits length / width

mm

±2 / ±1.5%

±2 / ±1.5%

DSTU EN 13162

Thickness tolerance class T2

Logistics parameters:

Length, mm 1200 1200
Width, mm 600 600
Thickness, mm 50 100
Quantity per package, boards, pcs 12 6
Quantity per package, m2 8.64 4.32
Quantity per package, m3 0.432 0.432
Quantity per pallet, packages, pcs 24 24
Quantity per pallet, m3 10.368 10.368
Loading capacity in truck, volume 92 m3 114.048 114.048