TU U V.2.7.-26.8-35492904-004:2010 with amendment 4
Rock mineral wool slabs
Product Description:
Fire Protection Slabs for Concrete Lamel are non-combustible, hydrophobized, thermal and sound insulation slabs made of mineral wool based on basalt group rocks.
Can be manufactured with aluminum foil or fiberglass coating.
Application:
In civil and industrial construction, during new construction and reconstruction of buildings and structures for various purposes, as fire protection and thermal insulation for reinforced concrete structures (reinforced concrete columns and floors). The boards are certified as the main element of the concrete fire protection system.
Application instructions:
Installation according to the Fire Protection Work Regulations “SD-FIRE PROTECTION Concrete fire protection system, consisting of mineral wool boards of the “Concrete Fire Protection Boards (MC, AF, SS, SP)” brand and anchoring metal elements (anchor+washer) HILTI IDMS”.
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Board Fire protection for concrete lamel |
Test Method |
| Density |
kg/m3 |
70-90 |
DSTU B V.2.7-38-95 |
| Thermal conductivity, λ25 |
W/mK |
0,037* |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λA |
W/mK |
0,041** |
DSTU B.V.2.7-182:2009 |
| Thermal conductivity, λB |
W/mK |
0,043** |
DSTU B.V.2.7-182:2009 |
| Compressive strength, not less than |
kPa |
50 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
0,5 |
DSTU B V.2.7-38-95 |
| Organic matter content, not more than |
% |
3 |
DSTU B V.2.7-38-95 |
| Flammability |
degree |
NG |
DSTU B V.2.7-70-98 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1000 (±2%) |
DSTU B V.2.7-38-95 |
| Width |
mm |
200 (± 1.5%) |
DSTU B V.2.7-38-95 |
| Thickness (in 10 mm increments) |
mm |
60-150 in 10 mm increments (+ 3 mm; – 2 mm) |
DSTU B V.2.7-38-95 |
Product Description:
SWEETONDALE Pipe Section is a thermal insulation pipe section made of mineral wool based on basalt rock. Can be manufactured laminated with reinforced aluminum foil. Laminated pipe sections have a self-adhesive foil overlap, which significantly simplifies installation.
Application:
Thermal insulation of process pipelines at facilities in various industries (including food industry) and construction sector.
Maximum application temperature +650°C.
Combustibility group NG according to DSTU B V.2.7-19-95 (GOST 30244-94).
Used in civil and industrial construction for new construction, reconstruction, and insulation of pipelines for various purposes.
Can be used on round air ducts as a thermal insulation layer.
Application instructions:
According to the “Album of Technical Solutions for Equipment and Pipeline Thermal Insulation Systems” and installation instructions “Pipe Section Installation”.
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Pipe sections are packed in cardboard boxes.

Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Pipe Section 80 |
Pipe Section 120 |
Test Method |
| Density |
kg/m3 |
70-110 |
110-140 |
DSTU B V.2.7-38-95 |
| Compaction coefficient, Kc* |
– |
1-1,05 |
1-1,05 |
SNiP 2.04.14-88 |
| Thermal conductivity, λ25 |
W/m K |
0,038** |
0,037 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ125 |
W/m K |
0,048** |
0,048 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ300 |
W/m K |
0,086** |
0,087 |
DSTU B V.2.7-105-2000 |
| Tensile strength, not less than |
kPa |
15 |
20 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
0,5 |
0,5 |
DSTU B V.2.7-38-95 |
| Organic matter content |
%, not more than |
4,5 |
4,5 |
DSTU B V.2.7-38-95 |
| Combustibility class |
group |
NG |
NG |
DSTU B V.2.7-70-98 |
*- the range of diameters corresponds to standard pipe diameters;
**- according to protocol No. 60K/17.
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
| Pipe section length |
mm |
1000 (±2%) |
| Pipe diameter (internal diameter of pipe section)* |
mm |
18-324 (+5 mm; -2 mm) |
| Pipe section wall thickness |
mm |
20-100 (in increments of 10); 120 (+5 mm; -2 mm) |
TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)
Rock mineral wool slabs
Product Description:
Concrete Fire Protection Boards are non-combustible, hydrophobized, thermal and sound insulation boards made of mineral wool based on basalt group rocks.
Can be manufactured with aluminum foil or fiberglass coating.
Application:
The boards are intended for use in civil and industrial construction, in new construction and reconstruction of buildings and structures for various purposes as fire protection and thermal insulation of reinforced concrete structures (reinforced concrete columns and floors).
The boards are certified as the main element of the concrete fire protection system.
Application instructions:
Installation according to the Fire Protection Work Regulations “SD-FIRE PROTECTION Concrete fire protection system, consisting of mineral wool boards of the “Concrete Fire Protection Boards (MC, AF, SS, SP)” brand and anchoring metal elements (anchor+washer) HILTI IDMS”.
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Board Concrete Fire Protection 80 |
Test Method |
| Density |
kg/m3 |
70-90 |
DSTU B V.2.7-38-95 |
| Thermal conductivity, λ25 |
W/mK |
0,037* |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λA |
W/mK |
0,038** |
DSTU B.V.2.7-182:2009 |
| Thermal conductivity, λB |
W/mK |
0,040** |
DSTU B.V.2.7-182:2009 |
| Compressive strength at 10% linear deformation, not less than |
kPa |
10 |
DSTU B V.2.7-38-95 |
| Compressive strength, not less than |
kPa |
– |
DSTU B V.2.7-38-95 |
| Water absorption during partial immersion, not more than |
% |
10 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
0,5 |
DSTU B V.2.7-38-95 |
| Organic matter content, not more than |
% |
3 |
DSTU B V.2.7-38-95 |
| Flammability |
degree |
NG |
DSTU B V.2.7-70-98 |
*-according to protocol No. 58K/17;
**-according to protocol No. 96K/17.
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 (± 2%) |
DSTU B V.2.7-38-95 |
| Width |
mm |
600 (± 1.5%) |
DSTU B V.2.7-38-95 |
| Thickness (in 10 mm increments) |
mm |
50-150 with 10 mm increments (+ 3 mm; – 2 mm) |
DSTU B V.2.7-38-95 |
Rigid Stone Wool Board
Product Description:
Technical insulation – rigid stone wool board. The boards are manufactured from mineral wool based on basalt group rock.
Can be produced laminated with reinforced aluminum foil or fiberglass cloth on one side. A significant difference between Technical Insulation boards and general construction insulation is the wide operating temperature range of the board.
Application:
Designed for thermal insulation of air ducts, gas ducts, electrostatic precipitators, tanks, boilers, process equipment, flat vertical and horizontal surfaces, furnaces, at facilities in various industries and equipment of engineering systems in residential, civil and industrial construction. The board operates in a wide temperature range of the insulated surface, depending on the board grade from -180°C to +750°C, while conventional building insulation is designed for a temperature range from -60°C to +80°C.
Application instructions:
According to the “Album of Technical Solutions for Equipment and Pipeline Thermal Insulation Systems” and installation instructions “Pipe Section Installation”.
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging.
Main physical and mechanical characteristics:
|
Parameter |
Unit requirement |
Technical insulation |
Test Method |
||||||
|
40 |
60 |
80 |
100 |
120 |
150 |
180 |
|||
| Density |
kg/m3 |
40 (±10) |
60 (±10) |
70-85 |
100 (±10) |
120 (±20) |
140-175 |
180 (±10) |
DSTU B V.2.7-38-95 |
| Thermal conductivity, λ25 |
W/m·K |
0,037 |
0,036 |
0,037* |
0,037 |
0,037 |
0,038 |
0,038 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ125 |
W/m·K |
0,056 |
0,055 |
0,045* |
0,051 |
0,050 |
0,051 |
0,051 |
DSTU B V.2.7-105-2000 |
| Thermal Conductivity, Λ300 |
W/m·K |
|
|
0,087* |
|
|
|
|
DSTU B V.2.7-105-2000 |
| Compressive strength at 10% linear deformation, not less than |
kPa |
– |
– |
– |
10 |
10 |
20 |
40 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
0,5 |
DSTU B V.2.7-38-95 |
||||||
| Organic matter content, not more than |
% |
4,5 |
DSTU B V.2.7-38-95 |
||||||
| Combustibility class |
degree |
NG |
DSTU B V.2.7-70-98 |
||||||
*-according to protocol No. 61K/17.
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
| Length |
mm |
1200; 1000 (+5%; -2%) |
| Width |
mm |
500; 600 (±1.5%) |
| Thickness (depending on board density) |
mm |
40 kg/m³ – from 50-200 mm 60 kg/m³ – from 50-200 mm 80 kg/m³ – from 50-200 mm 100 kg/m³ – from 50-170 mm 120 kg/m³ – from 50-140 mm 150 kg/m³ – from 30-100 mm 180 kg/m³ – from 30-90 mm |
TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)
Low-combustibility thermal and sound insulation mats
Product Description:
Lamellar mats are low-combustibility thermal and sound insulation mats formed from stone wool strips (lamellas) bonded to reinforced foil. This produces a product with increased compressive strength compared to traditional mats and less deformation during installation.
In standard configuration, the mats are covered with reinforced aluminum foil. The foil covering with sealed seams serves as a vapor barrier layer, which eliminates the need for an additional vapor barrier layer on cold pipelines and air ducts.
The base of the mats consists of non-combustible stone wool lamellas.
Application:
Thermal and vapor insulation of air ducts, ventilation equipment, tanks, as well as pipelines and flat surfaces. In civil and industrial construction, for new construction and pipeline installation, and reconstruction of buildings and structures for various purposes.
Applicable at insulated surface temperatures up to +250°C on the stone wool side (on the foil side, maximum application temperature is +80°C). Provides the following functions:
thermal insulation;
vapor barrier;
finished decorative covering for indoor installations (outdoor installations require a protective covering layer).
Application instructions:
In accordance with the “Album of Technical Solutions for Thermal Insulation Systems for Equipment and Pipelines.”
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging.
Main Physical and Mechanical Characteristics
| Parameter |
Unit of measurement |
Lamellar Mat 35 |
Lamellar Mat 50 |
Test Method |
| Density |
kg/m3 |
30-45 |
40-55 |
DSTU B V.2.7-38-95 |
| Compression coefficient, Kc |
– |
1 |
1 |
SNiP 2.04.14-88 |
| Thermal conductivity, λ25 |
W/mK |
0,040* |
0,040 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ125 |
W/mK |
0,062* |
0,062 |
DSTU B V.2.7-105-2000 |
| Compressibility under 2 kPa load, not more than |
% |
40 |
40 |
DSTU B V.2.7-38-95 |
| Resilience, not less than |
% |
– |
65 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
1 |
1 |
DSTU B V.2.7-38-95 |
| Organic matter content, not more than |
% |
4,5 |
4,5 |
DSTU B V.2.7-38-95 |
*according to protocol No. 59K/17.