TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
ULTRAWOOL BRICK is a non-combustible, hydrophobized thermal and acoustic insulation board made from mineral wool based on basalt group rocks.
ULTRAWOOL BRICK boards are recommended for use as thermal and acoustic insulation in various types of multi-layer masonry, frame walls (including exterior walls) with different types of external cladding (siding).
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material ensures reliable and durable packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
42±4 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,036 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.039 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
– |
DSTU EN 826 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1000, 1200 |
DSTU EN 822 |
| Width |
mm |
500, 600 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
50 – 200 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T4 | ||
Logistics parameters:
| Length, mm | 1200 | 1200 |
| Width, mm | 600 | 600 |
| Thickness, mm50100 | ||
| Quantity per package, boards, pcs., | 8 | 4 |
| Quantity per package, m2 | 5.760 | 2.880 |
| Quantity per package, m3 | 0.288 | 0.288 |
| Quantity per pallet, packages, pcs | 24 | 24 |
| Quantity per pallet, m3 | 6.912 | 6.912 |
| Loading capacity in truck, volume 92 m3 | 76.032 | 76.032 |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
ULTRAWOOL COTTAGE are non-combustible, hydrophobized thermal and sound insulation boards made of mineral wool based on basalt group rock.
ULTRAWOOL COTTAGE boards are designed for use as a thermal insulation layer in facade systems with external plaster coating on low-rise buildings and structures (up to 10 m high), as well as on wall sections located inside glazed loggias and balconies, stairways and landings of multi-story buildings regardless of their height.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material ensures reliable and durable packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
105±10 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,036 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.039 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
20 |
DSTU EN 826 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
10 |
DSTU EN 1607 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200, 2000, 2400 |
DSTU EN 822 |
| Width |
mm |
600, 1000 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
50 – 200 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T5 | ||
Logistics parameters:
| Length, mm | 1200 | 1200 | 1200 |
| Width, mm | 600 | 600 | 600 |
| Thickness, mm | 50 | 100 | 150 |
| Quantity per package, boards, pcs | 6 | 3 | 2 |
| Quantity per package, m2 | 4.32 | 2.16 | 1.44 |
| Quantity per package, m3 | 0.216 | 0.216 | 0.216 |
| Quantity per pallet, packages, pcs | 32 | 32 | 32 |
| Quantity per pallet, m3 | 6.912 | 6.912 | 6.912 |
| Loading capacity in truck, volume 92, m3 | 76.032 | 76.032 | 76.032 |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
ULTRAWOOL LIGHT is a non-combustible, hydrophobized thermal and acoustic insulation board made from rock wool based on basalt group minerals.
ULTRAWOOL LIGHT material is recommended for use in cottage and low-rise construction as thermal and acoustic insulation for horizontal, sloped, and vertical structures (frame walls, siding-clad walls, floors and ceilings, partitions).
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material ensures reliable and durable packaging of the boards, their protection during loading and unloading operations, transportation and storage.

Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
30±5 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,039 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.041 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
– |
DSTU EN 826 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 |
DSTU EN 822 |
| Width |
mm |
600, 1000 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
50-100, 150-200 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T2 | ||
Logistics parameters:
| Length, mm | 1200 | 1200 |
| Width, mm | 600 | 600 |
| Thickness, mm50100 | ||
| Quantity per package, boards, pcs., | 8 | 4 |
| Quantity per package, m2 | 5.760 | 2.880 |
| Quantity per package, m3 | 0.288 | 0.288 |
| Quantity per pallet, packs, pcs | 36 | 36 |
| Quantity per pallet, m3 | 10.368 | 10.368 |
| Standard loading in a 92 m3 truck | 114.048 | 114.048 |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL BLOCK are non-combustible, hydrophobized thermal and sound insulation boards made of mineral wool based on basalt group rocks.
THERMOWOOL BLOCK boards are recommended for use in industrial and civil construction as thermal and sound insulation for various types of multi-layer masonry, frame walls (including exterior walls) with different types of external finishes (siding). They are also used as the first (inner) thermal insulation layer in ventilated facade systems with an air gap in a two-layer configuration.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material ensures reliable and durable packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions
Main physical and mechanical characteristics:
|
Parameter |
THERMOWOOL BLOCK STANDARD 45 |
THERMOWOOL BLOCK OPTIMA 55 |
THERMOWOOL BLOCK PROF 65 |
Test Method |
| Density, kg/m3 |
45±5 |
55±5 |
65±5 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,036 |
0,035 |
0,036 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.039 |
0.040 |
0.040 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
0,5 |
0,5 |
5 |
DSTU EN 826 |
| Long-term water absorption, kg/m2, not more than |
3 |
3 |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
1 |
1 |
EN 1609 |
| Reaction to fire |
A1 |
A1 |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
NG |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
50 |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
THERMOWOOL BLOCK STANDARD 45 |
THERMOWOOL BLOCK OPTIMA 55 |
THERMOWOOL BLOCK PROF 65 |
Test Method |
||
| Length |
mm |
1200 |
1200 |
1200 |
DSTU EN 822 |
||
| Width |
mm |
600 |
600 |
600 |
DSTU EN 822 |
||
| Thickness (in 10 mm increments) |
mm |
50 – 200 |
50 – 200 |
50 – 200 |
DSTU EN 823 |
||
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
±2 / ±1.5% |
±2 / ±1.5% |
DSTU EN 13162 |
||
| Thickness tolerance class | T4 | ||||||
Logistics parameters:
| Length, mm | 1200 | 1200 |
| Width, mm | 600 | 600 |
| Thickness, mm50100 | ||
| Quantity per package, boards, pcs | 12 | 6 |
| Quantity per package, m2 | 8.64 | 4.32 |
| Quantity per package, m3 | 0.432 | 0.432 |
| Quantity per pallet, packages, pcs | 16 | 16 |
| Quantity per pallet, m3 | 6.912 | 6.912 |
| Loading capacity in truck, volume 92 m3 | 76.032 | 76.032 |
TU U V.2.7-23.9-35492904-001:2013
Product Description:
TECHNOBLOCK is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rocks.
Application:
TECHNOBLOCK boards are recommended for use in individual, cottage, and low-rise construction as thermal and sound insulation for various types of multi-layer masonry, frame walls (including exterior walls) with different types of external finishes (siding). They are also suitable as the first (inner) thermal insulation layer in ventilated facade systems with an air gap in a two-layer configuration.
Storage:
The boards must be stored packaged and stacked on pallets, separated by grade and size. Throughout the entire storage period, the material must be protected from precipitation. The height of the stack during storage must not exceed 3 m.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material must ensure reliable and secure packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
TECHNOBLOCK STANDARD |
Test Method |
|
Compressibility |
% |
not more than |
10 |
DSTU B V.2.7-38-95 |
|
Flammability |
degree |
– |
Incombustible |
DBN V.1.1-7-2016 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,036 0,039* 0,041* |
DSTU B V.2.7-105-2000 DSTU B V.2.7-182:2009 DSTU B V.2.7-182:2009 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
GOST 25898-2012 |
|
Moisture content by mass |
% |
not more than |
0,5 |
DSTU B V.2.7-38-95 |
|
Water absorption during partial immersion by mass |
% |
not more than |
10 |
DSTU B V.2.7-38-95 |
|
Organic matter content |
% |
not more than |
2,5 |
DSTU B V.2.7-38-95 |
|
Density |
kg/m3 |
– |
45±5 |
DSTU B V.2.7-38-95 |
|
Effective service life |
years |
not less than |
50 |
DSTU B V.2.7-182:2009 |
* – according to Protocol No. 43k/22 of SE NDIBK
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1200 (±10) |
DSTU B V.2.7-38-95 |
|
Width |
mm |
600 (±5) |
DSTU B V.2.7-38-95 |
|
Thickness (in 10 mm increments) |
mm |
50 – 200 (+5,-2) |
DSTU B V.2.7-38-95 |
|
Length, mm |
1200 |
1200 |
|
Width, mm |
600 |
600 |
|
Thickness, mm |
50 |
100 |
|
Quantity per package, boards, pcs |
12 |
6 |
|
Quantity per package, m2 |
8,64 |
4,32 |
|
Quantity per package, m3 |
0,432 |
0,432 |
|
Quantity per pallet, packages, pcs |
16 |
16 |
|
Quantity per pallet, m3 |
6,912 |
6,912 |
|
Loading capacity in a vehicle with a volume of 92 m3 |
76,032 |
76,032 |
TU U V.2.7-23.9-35492904-005:2015
Non-combustible stone wool boards made from gabbro-basalt rock
Product Description:
TECHNOFACE COTTAGE is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rocks.
Application:
TECHNOFACE COTTAGE boards are designed for use as a thermal insulation layer in facade systems with an external plaster layer on low-rise buildings and structures (up to 10 m in height), as well as on wall sections located inside glazed loggias and balconies, stairways and landings of multi-story buildings regardless of their height. Also as a thermal insulation layer in facade systems with plastering over galvanized steel reinforcing mesh.
Storage:
Boards must be stored packaged and stacked on pallets separately by grade and size. Throughout the entire storage period, the material must be protected from atmospheric precipitation. The height of the board stack during storage must not exceed 3 m.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material must ensure reliable and secure packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
Value |
Test Method |
|
Tensile strength limit in the direction perpendicular to the surface |
MPa |
not less than |
0,01 |
DSTU B V.2.7-38 |
|
Compressive strength at 10% linear deformation |
MPa |
not less than |
0,02 |
DSTU B V.2.7-38 |
|
Flammability |
degree |
– |
Incombustible |
DBN V.1.1-7 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,038 0,039* 0,041* |
DSTU B V.2.7-105 DSTU B V.2.7-182 DSTU B V.2.7-182 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
DSTU B V.2.7-253 |
|
Moisture content by mass |
% |
not more than |
0,5 |
DSTU B V.2.7-38 |
|
Water absorption during partial immersion by mass |
% |
not more than |
10 |
DSTU B V.2.7-38 |
|
Organic matter content |
% |
not more than |
4,5 |
DSTU B V.2.7-38 |
|
Density |
kg/m3 |
– |
105±10 |
DSTU B V.2.7-38 |
|
Effective service life |
years |
Not less than |
50 |
DSTU B V.2.7-182 |
* – according to Protocol No. 47-16/20 of SE NDIBMV
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
|
Length |
mm |
1000, 2000, 2400 (±10) |
1200, 2000, 2400 (±10) |
DSTU B V.2.7-38 |
|
Width |
mm |
500 (±5) |
600, 1000 (±5) |
DSTU B V.2.7-38 |
|
Thickness (in 10 mm increments) |
mm |
50 – 200 (±2) |
DSTU B V.2.7-38 |
|
|
Logistics Parameters |
|||
|
Length, mm |
1200 |
1200 |
1200 |
|
Width, mm |
600 |
600 |
600 |
|
Thickness, mm |
50 |
100 |
150 |
|
Quantity per package, boards, pcs |
6 |
3 |
2 |
|
Quantity per package, m2 |
4,32 |
2,16 |
1,44 |
|
Quantity per package, m3 |
0,216 |
0,216 |
0,216 |
|
Quantity per pallet, packages, pcs |
32 |
32 |
32 |
|
Quantity per pallet, m3 |
6,912 |
6,912 |
6,912 |
|
Loading rate in vehicle, volume, m3 |
76,032 |
76,032 |
76,032 |
TU U V.2.7-23.9-35492904-001:2013
Product Description:
TECHNOBLOCK is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rocks.
Application:
TECHNOBLOCK slabs are recommended for use in industrial and civil construction as thermal and sound insulation for various types of multilayer masonry, frame walls (including external) with different types of external finishing (siding). They are also used as the first (internal) thermal insulation layer in ventilated facade systems with an air gap in a two-layer configuration.
Storage:
The boards must be stored packaged and stacked on pallets, separated by grade and size. Throughout the entire storage period, the material must be protected from precipitation. The height of the stack during storage must not exceed 3 m.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material must ensure reliable and secure packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
TECHNOBLOCK |
TECHNOBLOCK |
Test Method |
|
Compressibility |
% |
not more than |
8 |
5 |
DSTU B V.2.7-38-95 |
|
Flammability |
degree |
– |
Incombustible |
Incombustible |
DBN V.1.1-7-2016 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,036 0,040 0,043 |
0,035 0,040 0,043 |
DSTU B V.2.7-105-2000 DSTU B V.2.7-182:2009 DSTU B V.2.7-182:2009 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
0,3 |
GOST 25898-2012 |
|
Moisture content by mass |
% |
not more than |
0,5 |
0,5 |
DSTU B V.2.7-38-95 |
|
Water absorption during partial immersion by mass |
% |
not more than |
10 |
10 |
DSTU B V.2.7-38-95 |
|
Organic matter content |
% |
not more than |
2,5 |
2,5 |
DSTU B V.2.7-38-95 |
|
Density |
kg/m3 |
– |
55±5 |
65±5 |
DSTU B V.2.7-38-95 |
|
Effective service life |
years |
not less than |
50 |
50 |
DSTU B V.2.7-182:2009 |
* – according to Protocol No. 36k/13 of the State Enterprise NDIBK
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1000, 1200 (±10) |
DSTU B V.2.7-38-95 |
|
Width |
mm |
500, 600 (±5) |
DSTU B V.2.7-38-95 |
|
Thickness (in 10 mm increments) |
mm |
50 – 200 (+5,-2) |
DSTU B V.2.7-38-95 |
|
Length, mm |
1200 |
1200 |
|
Width, mm |
600 |
600 |
|
Thickness, mm |
50 |
100 |
|
Quantity per package, slabs, pcs. |
12 |
6 |
|
Quantity per package, m2 |
8,64 |
4,32 |
|
Quantity per package, m3 |
0,432 |
0,432 |
|
Quantity per pallet, packages, pcs |
16 |
16 |
|
Quantity per pallet, m3 |
6,912 |
6,912 |
|
Loading capacity in a vehicle with a volume of 92 m3 |
76,032 |
76,032 |
TU U V.2.7-26.8-35492904-002:2008 (with amendments 1, 2)
Non-combustible stone wool boards made from gabbro-basalt rock
Product Description:
ROCKLITE LITE is a non-combustible, hydrophobized thermal and acoustic insulation board made from mineral wool based on basalt group rocks.
Application:
ROCKLITE LITE material is recommended for use in cottage and low-rise construction as thermal and acoustic insulation for horizontal, inclined, and vertical structures (frame walls, siding-clad walls, floors and ceilings, partitions).
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
ROCKLITE LITE |
Test Method |
|
Flammability |
degree |
– |
Incombustible |
DBN V.1.1-7-2016 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,038* 0,041* 0,042* |
DSTU B V.2.7-105-2000 DSTU B V.2.7-182:2009 DSTU B V.2.7-182:2009 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
GOST 25898-2012 |
|
Moisture content by mass |
% |
not more than |
0,5 |
DSTU B V.2.7-38-95 |
|
Water absorption during partial immersion |
% by weight |
not more than |
15 |
DSTU B V.2.7-38-95 |
|
Organic matter content |
% |
not more than |
2,5 |
DSTU B V.2.7-38-95 |
|
Density |
kg/m3 |
not more than |
35 |
DSTU B V.2.7-38-95 |
|
Effective service life |
years |
not less than |
50* |
DSTU B V.2.7-182:2009 |
* – according to Protocol No. 37k/22 of SE NDIBK
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1200 (±10) |
DSTU B V.2.7-38-95 |
|
Width |
mm |
600, 1000 (±5) |
DSTU B V.2.7-38-95 |
|
Thickness (in 10 mm increments) |
mm |
50-100, 150-200(±5) |
DSTU B V.2.7-38-95 |
|
Length, mm |
1200 |
1200 |
|
Width, mm |
600 |
600 |
|
Thickness, mm |
50 |
100 |
|
Quantity per package, boards, pcs |
8 |
4 |
|
Quantity per package, m2 |
5,760 |
2,880 |
|
Quantity per package, m3 |
0,288 |
0,288 |
|
Quantity per pallet, packages, pcs |
36 |
36 |
|
Quantity per pallet, m3 |
10,368 |
10,368 |
|
Loading capacity in a vehicle with a volume of 92 m3 |
114,048 |
114,048 |