TU U 23.9-32944149-013:2024

Roll roofing and waterproofing material

Product Description and Scope of Application

HYDROBASE LIGHT consists of a base made of fiberglass or polyester fabric or a combined base, coated on both sides with bituminous binder, with protective layers on top in the form of coarse-grained granules or polymer film and on the bottom in the form of polymer film. The materials are manufactured for torch-on application.

Depending on the type of protective layers and area of application, the following grades are available:

HYDROBASE LIGHT K – with coarse-grained granules on the face side and polymer film on the torch-on application side of the sheet; used for installation of the top layer of the roofing membrane;

HYDROBASE LIGHT P – with polymer film on the face and bottom sides of the sheet; used for installation of the bottom layers of the roofing membrane and waterproofing of building structures.

Transportation and Storage

Transportation is carried out by all types of transport in covered vehicles in accordance with the Cargo Transportation Rules applicable to the given type of transport. Throughout the entire storage period, the material must be protected from atmospheric precipitation. Rolls are stored vertically on pallets in a single row by height.

Packaging Information

The material is packaged in UV-stabilized film and supplied on pallets

Application Instructions

In accordance with SWEETONDALE Installation Instructions

Main characteristics

Parameter name

HYDROBASE LIGHT P

HYDROBASE LIGHT K

Test Method

Mass per unit area, kg/m²*

2,5

3,5

EN 1849-1

Watertightness at 2 kPa pressure for 24 hours

EN 1928

Watertightness at 60 kPa pressure for 24 hours

No water penetration

No water penetration

EN 1928

Tensile strength along / across the sheet, N, not less than for material:

on fiberglass fabric

on polyester fabric

294/-

343/-

294/-

343/-

DSTU B V.2.7-83

Flexibility on a bar with a radius of (25.0±0.2) mm at temperature, °C, maximum

0

0

DSTU B V.2.7-83

Flow resistance at elevated temperature, °C

≥80

≥80

EN 1110

Loss of coarse-grained surfacing, g/sample, maximum

3

DSTU B V.2.7-83

Reaction to fire Class E DSTU EN 13501-1
Type of protective coating:

top side

torch-on side

film without logo

film without logo

slate

film without logo

Length/width, m

15×1

10×1

Pallet packaging

white heat-shrink bag with logo

* – deviation from the nominal value of 1 m² mass shall not exceed ±0.25 kg

 

TU U 23.9-32944149-013:2024

Roll roofing and waterproofing material

Product Description and Scope of Application

HYDROBASE STANDARD consists of a base made of fiberglass or polyester fabric or a combined base, coated on both sides with bituminous binder, with protective layers on top in the form of coarse-grained granules or polymer film and on the bottom in the form of polymer film. The materials are manufactured for torch-on application.

Depending on the type of protective layers and area of application, the following grades are available:

HYDROBASE STANDARD K – with coarse-grained granules on the face side and polymer film on the torch-on application side of the sheet; used for installation of the top layer of the roofing membrane;

HYDROBASE STANDARD P – with polymer film on the face and bottom sides of the sheet; used for installation of the bottom layers of the roofing membrane and waterproofing of building structures

Transportation and Storage

Transportation is carried out by all types of transport in covered vehicles in accordance with the Cargo Transportation Rules applicable to the given type of transport. Throughout the entire storage period, the material must be protected from atmospheric precipitation. Rolls are stored vertically on pallets in a single row by height.

Packaging Information

The material is packaged in UV-stabilized film and supplied on pallets

Application Instructions

In accordance with SWEETONDALE Installation Instructions

Main characteristics

Parameter name

HYDROBASE STANDARD P

HYDROBASE STANDARD K

Test Method

Mass per unit area, kg/m²*

2,5

4,0

EN 1849-1

Watertightness at 2 kPa pressure for 24 hours

EN 1928

Watertightness at 60 kPa pressure for 24 hours

No water penetration

No water penetration

EN 1928

Tensile strength along / across the sheet, N, not less than for material:

on fiberglass fabric

on polyester fabric

294/-

343/-

294/-

343/-

DSTU B V.2.7-83

Flexibility on a bar with a radius of (25.0±0.2) mm at temperature, °C, maximum

-10

-10

DSTU B V.2.7-83

Flow resistance at elevated temperature, °C

≥90

≥90

EN 1110

Loss of coarse-grained surfacing, g/sample, maximum

2

DSTU B V.2.7-83

Reaction to fire Class E DSTU EN 13501-1
Type of protective coating:

top side

torch-on side

film without logo

film without logo

slate

film without logo

Length/width, m

15×1

10×1

Pallet packaging

white heat-shrink bag with logo

 

* – deviation from the nominal value of 1 m² mass shall not exceed ±0.25 kg

 

TU U 23.9-32944149-013:2024

Roll roofing and waterproofing material

Product Description and Scope of Application

HYDROBASE ULTRA consists of a base made of fiberglass or polyester fabric or a combined base, coated on both sides with bitumen-polymer binder, with protective layers on top in the form of coarse-grained granules or polymer film and on the bottom in the form of polymer film. The materials are manufactured for torch-on application.

Depending on the type of protective layers and area of application, the following grades are available:

HYDROBASE ULTRA K – with coarse-grained granules on the face side and polymer film on the torch-on side of the sheet; used for installation of the top layer of the roofing membrane;

HYDROBASE ULTRA P – with polymer film on the face and bottom sides of the sheet; used for installation of lower layers of the roofing membrane and waterproofing of building structures, as well as for vapor barrier.

Transportation and Storage

Transportation is carried out by all types of transport in covered vehicles in accordance with the Cargo Transportation Rules applicable to the given type of transport. Throughout the entire storage period, the material must be protected from atmospheric precipitation. Rolls are stored vertically on pallets in a single row by height.

Packaging Information

The material is packaged in UV-stabilized film and supplied on pallets

Application Instructions

In accordance with SWEETONDALE Installation Instructions

Main characteristics

Parameter name HYDROBASE ULTRA P HYDROBASE ULTRA K

Test Method

Mass per unit area, kg/m²*

3,0

4,0

EN 1849-1

3,5 **

4,5 **

Watertightness at 2 kPa pressure for 24 hours

No water penetration

EN 1928

Watertightness at 60 kPa pressure for 24 hours

No water penetration

EN 1928

Tensile strength along / across the sheet, N, not less than for material:

on fiberglass fabric

on polyester fabric

343/-

400/-

343/-

400/-

DSTU B V.2.7-83

Flexibility on a bar with a radius of (25.0±0.2) mm at temperature, °C, maximum

-15

-15

DSTU B V.2.7-83

Flow resistance at elevated temperature, °C

≥105

≥105

EN 1110

Loss of coarse-grained surfacing, g/sample, maximum

1

DSTU B V.2.7-83

Reaction to fire Class E DSTU EN13501-1
Type of protective coating:

top side

torch-on side

film without logo

film with logo

slate

film with logo

Length/width, m

15×1

10×1

Pallet packaging

white heat-shrink bag with logo

 

* – deviation from the nominal value of 1 m² mass shall not exceed ±0.25 kg

** – custom manufacturing is available upon request.

 

TU U V.2.7.-26.8-35492904-004:2010 with amendment 4

Rock mineral wool slabs

Product Description:

Fire Protection Slabs for Concrete Lamel are non-combustible, hydrophobized, thermal and sound insulation slabs made of mineral wool based on basalt group rocks.

Can be manufactured with aluminum foil or fiberglass coating.

Application:

In civil and industrial construction, during new construction and reconstruction of buildings and structures for various purposes, as fire protection and thermal insulation for reinforced concrete structures (reinforced concrete columns and floors). The boards are certified as the main element of the concrete fire protection system.

Application instructions:

Installation according to the Fire Protection Work Regulations “SD-FIRE PROTECTION Concrete fire protection system, consisting of mineral wool boards of the “Concrete Fire Protection Boards (MC, AF, SS, SP)” brand and anchoring metal elements (anchor+washer) HILTI IDMS”.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:

Parameter

Unit of measurement

Board

Fire protection for concrete lamel

Test Method

Density

kg/m3

70-90

DSTU B V.2.7-38-95

Thermal conductivity, λ25

W/mK

0,037*

DSTU B V.2.7-105-2000

Thermal conductivity, λA

W/mK

0,041**

DSTU B.V.2.7-182:2009

Thermal conductivity, λB

W/mK

0,043**

DSTU B.V.2.7-182:2009

Compressive strength, not less than

kPa

50

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

0,5

DSTU B V.2.7-38-95

Organic matter content, not more than

%

3

DSTU B V.2.7-38-95

Flammability

degree

NG

DSTU B V.2.7-70-98

 

 

Geometric parameters:

Parameter

Unit of measurement

Value

Test Method

Length

mm

1000 (±2%)

DSTU B V.2.7-38-95

Width

mm

200 (± 1.5%)

DSTU B V.2.7-38-95

Thickness (in 10 mm increments)

mm

60-150 in 10 mm increments (+ 3 mm; – 2 mm)

DSTU B V.2.7-38-95

 

 

 

 


 

TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)

Non-combustible, hydrophobized mineral wool boards

 

Product Description:

Metal Fire Protection Board is a non-combustible, hydrophobized, thermal and sound insulation board made of mineral wool based on basalt group rocks.

Application:

In civil and industrial construction for new construction and reconstruction of buildings and structures of various purposes as thermal insulation and fire protection of metal structures.

To increase the fire resistance limit of load-bearing metal structures with a fire resistance limit from 60 to 180 minutes.

Certified in the metal fire protection system and the air duct fire protection system.

Application instructions:

Installation according to the Fire Protection Work Regulations “SD-FIRE PROTECTION Metal Fire Protection System” for cladding metal structures, consisting of mineral wool boards of the “Metal Fire Protection Boards (MC, AF, SS, SP)” brand and Ceresit CM 17 adhesive”, “SD-FIRE PROTECTION Air Ducts Fire Protection System” for cladding steel air ducts, consisting of mineral wool boards of the “Metal Fire Protection Boards (MC, AF, SS, SP)” brand and Ceresit CM 17 adhesive”.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:

Parameter

Unit of measurement

Value

Test Method

Density

kg/m3

165 (±15)

DSTU B V.2.7-38

Thermal conductivity, *λ25

W/mK

0,037

DSTU B V.2.7-105

Thermal conductivity, **λA

W/mK

0,042

DSTU B.V.2.7-182

Thermal conductivity, **ΛB

W/mK

0,045

DSTU B.V.2.7-182

Compressive strength at 10% linear deformation, not less than

kPa

20

DSTU B V.2.7-38

Moisture content by mass, not more than

%

0,5

DSTU B V.2.7-38

Organic matter content, not more than

%

3

DSTU B V.2.7-38

Flammability

degree

NG

DSTU B V.2.7-70

*- according to protocol No. 56K/17;

 


**- according to protocol No. 94K/17.

 

Geometric parameters:

Parameter

Unit of measurement

Value

Length

mm

2400,1200 (±2%)

Width

mm

1000,600 (±1.5%)

Thickness

mm

30-70 in 10 mm increments (+3 mm; -2 mm)


 

TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)

Rock mineral wool slabs

Product Description:

Fire Protection Door Slab is a non-combustible thermal and acoustic insulation slab made from rock mineral wool based on basalt group rocks.

Application:

Fire Protection Door Slabs are specially designed and intended for fire protection insulation of fire-rated doors and gates.

Application instructions:

Installation of slabs in the frame of fire-rated doors and gates as fire protection filler is carried out based on structural features in accordance with the technical documentation of the door and gate manufacturer.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:

Parameter

Unit of measurement

Fire Protection Door Slab 110

Fire Protection Door Slab 190

Test Method

Density

kg/m3

100-120

170-200

DSTU B V.2.7-38-95

Thermal conductivity λ25

W/mK

0,037

0,038

DSTU B V.2.7-105-2000

Compressive strength at 10% linear deformation, not less than

kPa

10

20

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

0,5

0,5

DSTU B V.2.7-38-95

Organic matter content, not more than

%

3,0

3,0

DSTU B V.2.7-38-95

Flammability

degree

NG

NG

DSTU B V.2.7-70-98

 

Geometric parameters:

Parameter

Unit of measurement

Value

Test Method

Length

mm

1000; 1200; 2000; 2400 (±2%)

DSTU B V.2.7-38-95

Width

mm

200, 600; 1000; 1200 (±1.5%)

DSTU B V.2.7-38-95

Thickness (in 10 mm increments)

mm

50-140 in 10 mm increments (+5 mm; -2 mm)*, 30-80 in 10 mm increments (+5 mm; -2 mm)**

DSTU B V.2.7-38-95

 


*-for Fire Protection Door Slab 110;

 


**-for Fire Protection Door Slab 190.

TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)

Rock mineral wool slabs

Product Description:

Concrete Fire Protection Boards are non-combustible, hydrophobized, thermal and sound insulation boards made of mineral wool based on basalt group rocks.

Can be manufactured with aluminum foil or fiberglass coating.

Application:

The boards are intended for use in civil and industrial construction, in new construction and reconstruction of buildings and structures for various purposes as fire protection and thermal insulation of reinforced concrete structures (reinforced concrete columns and floors).

The boards are certified as the main element of the concrete fire protection system.

Application instructions:

Installation according to the Fire Protection Work Regulations “SD-FIRE PROTECTION Concrete fire protection system, consisting of mineral wool boards of the “Concrete Fire Protection Boards (MC, AF, SS, SP)” brand and anchoring metal elements (anchor+washer) HILTI IDMS”.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:

Parameter

Unit of measurement

Board

Concrete Fire Protection 80

Test Method

Density

kg/m3

70-90

DSTU B V.2.7-38-95

Thermal conductivity, λ25

W/mK

0,037*

DSTU B V.2.7-105-2000

Thermal conductivity, λA

W/mK

0,038**

DSTU B.V.2.7-182:2009

Thermal conductivity, λB

W/mK

0,040**

DSTU B.V.2.7-182:2009

Compressive strength at 10% linear deformation, not less than

kPa

10

DSTU B V.2.7-38-95

Compressive strength, not less than

kPa

DSTU B V.2.7-38-95

Water absorption during partial immersion, not more than

%

10

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

0,5

DSTU B V.2.7-38-95

Organic matter content, not more than

%

3

DSTU B V.2.7-38-95

Flammability

degree

NG

DSTU B V.2.7-70-98

*-according to protocol No. 58K/17;

 


**-according to protocol
No. 96K/17.

 

Geometric parameters:

Parameter

Unit of measurement

Value

Test Method

Length

mm

1200 (± 2%)

DSTU B V.2.7-38-95

Width

mm

600 (± 1.5%)

DSTU B V.2.7-38-95

Thickness (in 10 mm increments)

mm

50-150 with 10 mm increments (+ 3 mm; – 2 mm)

DSTU B V.2.7-38-95

 

 

 

 


 

Rigid Stone Wool Board

Product Description:

Technical insulation – rigid stone wool board. The boards are manufactured from mineral wool based on basalt group rock.

Can be produced laminated with reinforced aluminum foil or fiberglass cloth on one side. A significant difference between Technical Insulation boards and general construction insulation is the wide operating temperature range of the board.

Application:

Designed for thermal insulation of air ducts, gas ducts, electrostatic precipitators, tanks, boilers, process equipment, flat vertical and horizontal surfaces, furnaces, at facilities in various industries and equipment of engineering systems in residential, civil and industrial construction. The board operates in a wide temperature range of the insulated surface, depending on the board grade from -180°C to +750°C, while conventional building insulation is designed for a temperature range from -60°C to +80°C.

Application instructions:

According to the “Album of Technical Solutions for Equipment and Pipeline Thermal Insulation Systems” and installation instructions “Pipe Section Installation”.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:

Parameter

Unit requirement

Technical insulation

Test Method

40

60

80

100

120

150

180

Density

kg/m3

40 (±10)

60 (±10)

70-85

100 (±10)

120 (±20)

140-175

180 (±10)

DSTU B V.2.7-38-95

Thermal conductivity, λ25

W/m·K

0,037

0,036

0,037*

0,037

0,037

0,038

0,038

DSTU B V.2.7-105-2000

Thermal conductivity, λ125

W/m·K

0,056

0,055

0,045*

0,051

0,050

0,051

0,051

DSTU B V.2.7-105-2000

Thermal Conductivity, Λ300

W/m·K

0,087*

DSTU B V.2.7-105-2000

Compressive strength at 10% linear deformation, not less than

kPa

10

10

20

40

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

0,5

DSTU B V.2.7-38-95

Organic matter content, not more than

%

4,5

DSTU B V.2.7-38-95

Combustibility class

degree

NG

DSTU B V.2.7-70-98


*-according to protocol No. 61K/17.

 

Geometric parameters:

Parameter

Unit of measurement

Value

Length

mm

1200; 1000 (+5%; -2%)

Width

mm

500; 600 (±1.5%)

Thickness (depending on board density)

mm

40 kg/m³ – from 50-200 mm

60 kg/m³ – from 50-200 mm

80 kg/m³ – from 50-200 mm

100 kg/m³ – from 50-170 mm

120 kg/m³ – from 50-140 mm

150 kg/m³ – from 30-100 mm

180 kg/m³ – from 30-90 mm

 

 

 

 

 

 

 

 

 


TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)

Low-combustibility thermal and sound insulation mats

Product Description:

Lamellar mats are low-combustibility thermal and sound insulation mats formed from stone wool strips (lamellas) bonded to reinforced foil. This produces a product with increased compressive strength compared to traditional mats and less deformation during installation.

In standard configuration, the mats are covered with reinforced aluminum foil. The foil covering with sealed seams serves as a vapor barrier layer, which eliminates the need for an additional vapor barrier layer on cold pipelines and air ducts.

The base of the mats consists of non-combustible stone wool lamellas.

Application:

Thermal and vapor insulation of air ducts, ventilation equipment, tanks, as well as pipelines and flat surfaces. In civil and industrial construction, for new construction and pipeline installation, and reconstruction of buildings and structures for various purposes.

Applicable at insulated surface temperatures up to +250°C on the stone wool side (on the foil side, maximum application temperature is +80°C). Provides the following functions:

thermal insulation;

vapor barrier;

finished decorative covering for indoor installations (outdoor installations require a protective covering layer).

Application instructions:

In accordance with the “Album of Technical Solutions for Thermal Insulation Systems for Equipment and Pipelines.”

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main Physical and Mechanical Characteristics

Parameter

Unit of measurement

Lamellar Mat 35

Lamellar Mat 50

Test Method

Density

kg/m3

30-45

40-55

DSTU B V.2.7-38-95

Compression coefficient, Kc

1

1

SNiP 2.04.14-88

Thermal conductivity, λ25

W/mK

0,040*

0,040

DSTU B V.2.7-105-2000

Thermal conductivity, λ125

W/mK

0,062*

0,062

DSTU B V.2.7-105-2000

Compressibility under 2 kPa load, not more than

%

40

40

DSTU B V.2.7-38-95

Resilience, not less than

%

65

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

1

1

DSTU B V.2.7-38-95

Organic matter content, not more than

%

4,5

4,5

DSTU B V.2.7-38-95

*according to protocol No. 59K/17.