TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
ULTRAWOOL VIBRO is a non-combustible, hydrophobized thermal and sound insulation board made of mineral wool based on basalt group rocks. ULTRAWOOL VIBRO boards are designed for thermal and sound insulation of floating floors when laying concrete or cement screed directly on the thermal insulation.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material ensures reliable and durable packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
110±11 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,036 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.040 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
25 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
DSTU EN 1607 |
| Point load, N, minimum |
50 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 |
DSTU EN 822 |
| Width |
mm |
600 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
50-200 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T4 | ||
| Logistics Parameters: | ||
| Length, mm | 1200 | 1200 |
| Width, mm | 600 | 600 |
| Thickness, mm | 50 | 100 |
| Boards per pack, pcs | 6 | 3 |
| Coverage per pack, m2 | 4.32 | 2.160 |
| Volume per pack, m3 | 0.216 | 0.216 |
| Packs per pallet, pcs | 32 | 32 |
| Volume per pallet, m3 | 6.912 | 7.912 |
| Truck loading capacity (92 m3), m3 | 76.032 | 76.032 |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL FLOOR is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock. THERMOWOOL FLOOR boards are designed for thermal and sound insulation of floating floors when laying concrete or cement screed directly on the thermal insulation.
Transportation and Storage
Transportation of the boards is carried out in accordance with the requirements of DSTU B V.2.7-167. The boards must be stored packaged and stacked on pallets separately by grade and size. Throughout the entire storage period, the material must be protected from atmospheric precipitation. The height of the board stack during storage must not exceed 3 m. The guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions
Main physical and mechanical characteristics:
|
Parameter |
THERMOWOOL FLOOR STANDARD 110 |
THERMOWOOL FLOOR PROF 170 |
Test Method |
| Density, kg/m3 |
110±11 |
170±15 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,036 |
0,039 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.040 |
0.043 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
25 |
50 |
DSTU EN 826 |
| Point load, N, minimum |
50 |
600 |
EN 12430 |
| Impact sound insulation improvement index of the floor, dB
30mm 40mm 50mm |
36 38 40 |
|
DSTU B V.2.6-86 ISO 140-6 |
| Reaction to fire |
A1 |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
THERMOWOOL FLOOR STANDARD 110 |
THERMOWOOL FLOOR PROF 170 |
Test Method |
||
| Length |
mm |
1200 |
1200 |
DSTU EN 822 |
||
| Width |
mm |
600 |
600 |
DSTU EN 822 |
||
| Thickness (in 10 mm increments) |
mm |
50-200 |
30-100 |
DSTU EN 823 |
||
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
±2 / ±1.5% |
DSTU EN 13162 |
||
| Thickness tolerance class | T4 T5 | |||||
Logistics parameters:
| Length, mm | 1200 | 1200 |
| Width, mm | 600 | 600 |
| Thickness, mm | 50 | 30 |
| Quantity per package, boards, pcs | 6 | 7 |
| Quantity per package, m2 | 4.32 | 5.04 |
| Quantity per package, m3 | 0.216 | 0.151 |
| Quantity per pallet, packages, pcs | 32 | 48 |
| Quantity per pallet, m3 | 6.912 | 7.258 |
| Loading capacity in vehicle, volume 92, m3 | 76.032 | 79.834 |