TU U V.2.7-23.9-35492904-005:2015

Non-combustible stone wool boards made from gabbro-basalt rock

Product Description:

TECHNOVENT N is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rocks.

Application:

TECHNOVENT N boards are designed for use in civil and industrial construction during new construction and reconstruction of buildings and structures for various purposes as an inner layer in two-layer thermal insulation systems in ventilated facade systems with an air gap.

Storage:

The boards must be stored packaged and stacked on pallets, separated by grade and size. Throughout the entire storage period, the material must be protected from precipitation. The height of the stack during storage must not exceed 3 m.

Transportation:

Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material must ensure reliable and secure packaging of the boards, their protection during loading and unloading operations, transportation and storage.

Main physical and mechanical characteristics:

Parameter

Unit of measurement

Criterion

TECHNOVENT N   

TECHNOVENT N PROF 

Test Method

Compressive strength at 10% deformation

MPa

not less than

     –

DSTU B V.2.7-38

Flammability

degree

Incombustible

     NG

DBN V.1.1-7

Thermal conductivity:

λ25

λA

λB

W/m·K

not more than

0,038

0,039*

0,041*


  0.037

0.040**

0.043**

    DSTU B V.2.7-105

DSTU B V.2.7-182

DSTU B V.2.7-182

Compressibility

%

not more than

20

   10

DSTU B V.2.7-38

Vapor permeability

mg/(m·h·Pa)

not less than

0,3

  0,3

DSTU B V.2.7-253

Moisture content by mass

%

not more than

0,5

  0,5

DSTU B V.2.7-38

Water absorption by volume upon full immersion

%

not more than

1,5

  1,5

DSTU B V.2.7-38

Organic matter content

%

not more than

2,5

   2,5

DSTU B V.2.7-38

Density

kg/m3

36±4

45+5

DSTU B V.2.7-38

Effective service life

years

not less than

50

  50

DSTU B V.2.7-182

* – according to Protocol No. 42K/22 of SE NDIBK

** – according to Protocol No. 37-16/20 of SE NDIBMV


 

Geometric parameters:

Parameter

Unit of measurement

                                Value

Test Method

Length

mm

1000, 2000, 2400 (±10)

1200, 2000, 2400 (±10)

DSTU B V.2.7-38

Width

mm

500 (±5)

600, 1000 (±5)

DSTU B V.2.7-38

Thickness (in 10 mm increments)

mm

50 – 100, 130 – 200 (-2, +5)

DSTU B V.2.7-38


    

Logistics Parameters

Length, mm

1200

1200

1200

1200

Width, mm

600

600

600

600

Thickness, mm

50

100

150

200

Quantity per package, boards, pcs

12

6

4

3

Quantity per package, m2

8,64

4,32

2,88

2,16

Quantity per package, m3

0,432

0,432

0,432

0,432

Quantity per pallet, packages, pcs

16

16

16

16

Quantity per pallet, m3

6,912

6,912

6,912

6,912

Loading capacity in a vehicle with a volume of 92 m3

76,032

76,032

76,032

76,032


 

Product Description:

SWEETONDALE Pipe Section is a thermal insulation pipe section made of mineral wool based on basalt rock. Can be manufactured laminated with reinforced aluminum foil. Laminated pipe sections have a self-adhesive foil overlap, which significantly simplifies installation.

Application:

Thermal insulation of process pipelines at facilities in various industries (including food industry) and construction sector.

Maximum application temperature +650°C.

Combustibility group NG according to DSTU B V.2.7-19-95 (GOST 30244-94).

Used in civil and industrial construction for new construction, reconstruction, and insulation of pipelines for various purposes.

Can be used on round air ducts as a thermal insulation layer.

Application instructions:

According to the “Album of Technical Solutions for Equipment and Pipeline Thermal Insulation Systems” and installation instructions “Pipe Section Installation”.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Pipe sections are packed in cardboard boxes.

Main physical and mechanical characteristics:

Parameter

Unit of measurement

Pipe Section 80

Pipe Section 120

Test Method

Density

kg/m3

70-110

110-140

DSTU B V.2.7-38-95

Compaction coefficient, Kc*

1-1,05

1-1,05

SNiP 2.04.14-88

Thermal conductivity, λ25

W/m K

0,038**

0,037

DSTU B V.2.7-105-2000

Thermal conductivity, λ125

W/m K

0,048**

0,048

DSTU B V.2.7-105-2000

Thermal conductivity, λ300

W/m K

0,086**

0,087

DSTU B V.2.7-105-2000

Tensile strength, not less than

kPa

15

20

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

0,5

0,5

DSTU B V.2.7-38-95

Organic matter content

%, not more than

4,5

4,5

DSTU B V.2.7-38-95

Combustibility class

group

NG

NG

DSTU B V.2.7-70-98


*- the range of diameters corresponds to standard pipe diameters;

 


**- according to protocol No. 60K/17.

Geometric parameters:

Parameter

Unit of measurement

Value

Pipe section length

mm

1000 (±2%)

Pipe diameter (internal diameter of pipe section)*

mm

18-324 (+5 mm; -2 mm)

Pipe section wall thickness

mm

20-100 (in increments of 10); 120 (+5 mm; -2 mm)


Rigid Stone Wool Board

Product Description:

Technical insulation – rigid stone wool board. The boards are manufactured from mineral wool based on basalt group rock.

Can be produced laminated with reinforced aluminum foil or fiberglass cloth on one side. A significant difference between Technical Insulation boards and general construction insulation is the wide operating temperature range of the board.

Application:

Designed for thermal insulation of air ducts, gas ducts, electrostatic precipitators, tanks, boilers, process equipment, flat vertical and horizontal surfaces, furnaces, at facilities in various industries and equipment of engineering systems in residential, civil and industrial construction. The board operates in a wide temperature range of the insulated surface, depending on the board grade from -180°C to +750°C, while conventional building insulation is designed for a temperature range from -60°C to +80°C.

Application instructions:

According to the “Album of Technical Solutions for Equipment and Pipeline Thermal Insulation Systems” and installation instructions “Pipe Section Installation”.

Storage:

Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.

Transportation:

Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.

Packaging Information:

Polyethylene heat-shrink film is used for packaging.

Main physical and mechanical characteristics:

Parameter

Unit requirement

Technical insulation

Test Method

40

60

80

100

120

150

180

Density

kg/m3

40 (±10)

60 (±10)

70-85

100 (±10)

120 (±20)

140-175

180 (±10)

DSTU B V.2.7-38-95

Thermal conductivity, λ25

W/m·K

0,037

0,036

0,037*

0,037

0,037

0,038

0,038

DSTU B V.2.7-105-2000

Thermal conductivity, λ125

W/m·K

0,056

0,055

0,045*

0,051

0,050

0,051

0,051

DSTU B V.2.7-105-2000

Thermal Conductivity, Λ300

W/m·K

0,087*

DSTU B V.2.7-105-2000

Compressive strength at 10% linear deformation, not less than

kPa

10

10

20

40

DSTU B V.2.7-38-95

Moisture content by mass, not more than

%

0,5

DSTU B V.2.7-38-95

Organic matter content, not more than

%

4,5

DSTU B V.2.7-38-95

Combustibility class

degree

NG

DSTU B V.2.7-70-98


*-according to protocol No. 61K/17.

 

Geometric parameters:

Parameter

Unit of measurement

Value

Length

mm

1200; 1000 (+5%; -2%)

Width

mm

500; 600 (±1.5%)

Thickness (depending on board density)

mm

40 kg/m³ – from 50-200 mm

60 kg/m³ – from 50-200 mm

80 kg/m³ – from 50-200 mm

100 kg/m³ – from 50-170 mm

120 kg/m³ – from 50-140 mm

150 kg/m³ – from 30-100 mm

180 kg/m³ – from 30-90 mm