TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL ROOF PROF 160 is a non-combustible, hydrophobized thermal and sound insulation board made of mineral wool based on basalt group rocks. Used in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures for various purposes.
THERMOWOOL ROOF PROF 160 boards are designed for use as the primary thermal insulation layer in roofing systems with reinforced concrete or metal profiled decking with roofing membranes of all types, including installations without protective screeds.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
160±15 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,039 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.042 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
60 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
DSTU EN 1607 |
| Point load, N, minimum |
600 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 |
DSTU EN 822 |
| Width |
mm |
600 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
30-130 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T5 | ||
Logistics parameters:
| Thickness, mm | 30 | 100 | |
| Quantity per package, boards, pcs | 7 |
2 |
|
| Quantity per package, m2 | 5.040 | 1.440 | |
| Quantity per package, m3 | 0.1512 |
0.144 |
|
| Quantity per pallet, packages, pcs | 44 | 48 | |
| Quantity per pallet, m3 | 6.6528 | 6.912 | |
| Loading capacity per truck, volume, 92 m3 | 73.1808 | 76.032 | |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL ROOF STANDARD 140 is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock. Used in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures for various purposes.
THERMOWOOL ROOF STANDARD 140 boards are designed for use as the primary thermal insulation layer in roofing systems on reinforced concrete or metal profiled decking with roofing membranes of all types, including installations without protective screeds.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
140±14 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,038 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.042 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
45 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
DSTU EN 1607 |
| Point load, N, minimum |
450 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 |
DSTU EN 822 |
| Width |
mm |
600 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
40–160 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T5 | ||
Logistics parameters:
| Thickness, mm50100 | |||
| Quantity per package, boards, pcs, | 4 |
2 |
|
| Quantity per package, m2 | 2.880 | 1.440 | |
| Quantity per package, m3 | 0.144 |
0.144 |
|
| Quantity per pallet, packages, pcs | 48 | 48 | |
| Quantity per pallet, m3 | 6.912 | 6.912 | |
| Loading capacity per truck, volume, 92m3 | 76.032 | 76.032 | |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL ROOF V is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock. THERMOWOOL ROOF V boards are designed for use in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures for various purposes.
As the top layer in two- or three-layer roofing structures, as well as the bottom layer in multi-layer roofing structures, under high loads on roofs with profiled steel decking.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main physical and mechanical characteristics:
|
Parameter |
THERMOWOOL ROOF V EXTRA 170 |
THERMOWOOL ROOF V OPTIMA 180 |
THERMOWOOL ROOF V PROF 190 |
Test Method |
| Density, kg/m3 |
170±15 |
180±15 |
190±15 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,038 |
0,04 |
0,04 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.042 |
0.042 |
0.041 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
60 |
70 |
80 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
15 |
– |
DSTU EN 1607 |
| Point load, N, minimum |
650 |
700 |
700 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
3 |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
1 |
1 |
EN 1609 |
| Reaction to fire |
A1 |
A1 |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
NG |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
50 |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
THERMOWOOL ROOF V OPTIMA 180 |
THERMOWOOL ROOF V PROF 190 |
Test Method |
||
| Length |
mm |
1200 |
1200 |
1200 |
DSTU EN 822 |
||
| Width |
mm |
600 |
600 |
600 |
DSTU EN 822 |
||
| Thickness (in 10 mm increments) |
mm |
30-110 |
30-110 |
30-110 |
DSTU EN 823 |
||
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
±2 / ±1.5% |
±2 / ±1.5% |
DSTU EN 13162 |
||
| Thickness tolerance class | T5 | ||||||
Logistics parameters:
| Length, mm | 1200 | 1200 | 1200 |
| Width, mm | 600 | 600 | 600 |
| Thickness, mm | 100 | 40 | 50 |
| Quantity per package, boards, pcs | 2 | 5 | 4 |
| Quantity per package, m2 | 1.44 | 3.60 | 2.88 |
| Quantity per package, m3 | 0.144 | 0.144 | 0.144 |
| Quantity per pallet, packages, pcs | 48 | 48 | 48 |
| Quantity per pallet, m3 | 6.912 | 6.912 | 6.912 |
| Loading capacity per truck, volume 92 m3 | 76.032 | 76.032 | 76.032 |
TU U V.2.7-23.9-35492904-005:2015
Non-combustible stone wool boards made from gabbro-basalt rock
Product Description:
TEKHNORUF PROF is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock.
Application:
TEKHNORUF PROF boards are designed for use in civil and industrial construction as a thermal insulation layer for repairing old roofs and as an external layer in two- or three-layer structures.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167.
Boards are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material must ensure reliable and secure packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
Value |
Test Method |
|
Compressive strength under point load |
N |
not less than |
600 | DSTU B V.2.7-38 |
|
Compressive strength at 10% deformation |
MPa |
not less than |
0,06 |
DSTU B V.2.7-38 |
|
Flammability |
degree |
– |
Incombustible |
DBN V.1.1-7 |
|
Thermal conductivity: λ25 λA λb |
W/m·K |
not more than |
0,039 0,042* 0,045* |
DSTU B V.2.7-105 DSTU B V.2.7-182 DSTU B V.2.7-182 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
DSTU B V.2.7-253 |
|
Moisture content by mass |
% |
not more than |
0,5 |
DSTU B V.2.7-38 |
|
Water absorption by volume upon full immersion |
% |
not more than |
1,5 |
DSTU B V.2.7-38 |
|
Organic matter content |
% |
not more than |
4,5 |
DSTU B V.2.7-38 |
|
Density |
kg/m3 |
– |
160±15 |
DSTU B V.2.7-38 |
|
Effective service life |
years |
Not less than |
50* |
DSTU B V.2.7-182 |
* – according to Protocol No. 42-16/20 of SE NDIBMV
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1200 (±10) |
DSTU B V.2.7-38 |
|
Width |
mm |
600 (±5) |
DSTU B V.2.7-38 |
|
Thickness (in 10 mm increments) |
mm |
30 – 130 (±2) |
DSTU B V.2.7-38 |
|
Logistics Parameters |
|||
|
Thickness, mm |
30 |
100 |
|
|
Quantity per package, boards, pcs |
6 |
2
|
|
|
Quantity per package, m2 |
4,320 |
1,440 |
|
|
Quantity per package, m3 |
0,129 |
0,144
|
|
|
Quantity per pallet, packages, pcs |
52 |
48 |
|
|
Quantity per pallet, m3 |
6,739 |
6,912 |
|
|
Loading rate per vehicle, volume, 92 m3 |
74,131 |
76,032 |
|
TU U V.2.7-23.9-35492904-005:2015
Non-combustible stone wool boards made from gabbro-basalt rock
Product Description:
TECHNOROOF V is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock.
Application:
TECHNOROOF V boards are designed for use in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures for various purposes.
As an outer layer in two- or three-layer roofing structures, an outer layer for repairing old roofs, and as a lower layer in multi-layer roofing structures under high loads on profiled steel deck coverings.
Storage:
The boards must be stored packaged and stacked on pallets, separated by grade and size. Throughout the entire storage period, the material must be protected from precipitation. The height of the stack during storage must not exceed 3 m.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material must ensure reliable and secure packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
TECHNOROOF V EXTRA |
TECHNOROOF V OPTIMA |
TECHNOROOF V PROF |
Test Method |
|
Compressive strength at 10% linear deformation |
MPa |
not less than |
0,065 |
0,070 |
0,080 |
DSTU B V.2.7-38 |
|
Compressive strength under point load |
N |
not less than |
650 |
700 |
800 |
DSTU B V.2.7-167 |
|
Flammability |
degree |
– |
Incombustible |
Incombustible |
NG |
DBN V.1.1-7 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,040 0,043* 0,045* |
0,041 0,042** 0,044** |
0.041
0.041* 0.043* |
DSTU B V.2.7-105 DSTU B V.2.7-182 DSTU B V.2.7-182 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
0,3 |
0,3 |
DSTU B V.2.7-253 |
|
Moisture content by mass |
% |
not more than |
0,5 |
0,5 |
0,5 |
DSTU B V.2.7-38 |
|
Water absorption by volume upon full immersion |
% |
not more than |
1,5 |
1,5 |
1,5 |
DSTU B V.2.7-38 |
|
Organic matter content |
% |
not more than |
4,5 |
4,5 |
4,5 |
DSTU B V.2.7-38 |
|
Density |
kg/m3 |
– |
170±15 |
180±15 |
190+15 |
DSTU B V.2.7-38 |
|
Effective service life |
years |
Not less than |
50 |
50 |
50 |
DSTU B V.2.7-182 |
* – according to Protocol No. 111k-23 SE NDIBK
** – according to Protocol No. 35K/22 SE NDIBK
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1200 (±10) |
DSTU B V.2.7-38 |
|
Width |
mm |
600, 1000 (±5) |
DSTU B V.2.7-38 |
|
Thickness (in 10 mm increments) |
mm |
30-110, (±2) |
DSTU B V.2.7-38 |
|
Logistics Parameters |
|||
|
Length, mm |
1200 |
1200 |
1200 |
|
Width, mm |
600 |
600 |
600 |
|
Thickness, mm |
100 |
40 |
50 |
|
Quantity per package, boards, pcs |
2 |
5 |
4 |
|
Quantity per package, m2 |
1,44 |
3,60 |
2,88 |
|
Quantity per package, m3 |
0,144 |
0,144 |
0,144 |
|
Quantity per pallet, packages, pcs |
48 |
48 |
48 |
|
Quantity per pallet, m3 |
6,912 |
6,912 |
6,912 |
|
Loading capacity in vehicle with 92 m3 volume |
76,032 |
76,032 |
76,032 |