Main Physical and Mechanical Properties:
| Parameter |
Value |
Test Method |
| Density, kg/m³ |
105±20 |
ДСТУ Б В.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), max. |
0,043 |
ДСТУ Б EN 12667 |
| Compressive stress at 10% linear deformation, kPa, min. |
60 |
ДСТУ EN 826 |
| Tensile strength perpendicular to the board plane, kPa, min. |
100 |
ДСТУ EN 1607 |
| Shear strength, kPa, min. |
50 |
EN 12430 |
| Long-term water absorption, kg/m², max. |
3 |
EN 12087 |
| Short-term water absorption, kg/m², max. |
1 |
EN 1609 |
| Reaction to fire |
А1 |
ДСТУ EN 13501-1 |
| Flammability class |
NG |
ДБН В.1.1-7 |
Geometric parameters – made to order
TU U V.2.7-23.9-35492904-001:2013
Product Description:
TECHNOBLOCK is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rocks.
Application:
TECHNOBLOCK slabs are recommended for use in industrial and civil construction as thermal and sound insulation for various types of multilayer masonry, frame walls (including external) with different types of external finishing (siding). They are also used as the first (internal) thermal insulation layer in ventilated facade systems with an air gap in a two-layer configuration.
Storage:
The boards must be stored packaged and stacked on pallets, separated by grade and size. Throughout the entire storage period, the material must be protected from precipitation. The height of the stack during storage must not exceed 3 m.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material must ensure reliable and secure packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
TECHNOBLOCK |
TECHNOBLOCK |
Test Method |
|
Compressibility |
% |
not more than |
8 |
5 |
DSTU B V.2.7-38-95 |
|
Flammability |
degree |
– |
Incombustible |
Incombustible |
DBN V.1.1-7-2016 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,036 0,040 0,043 |
0,035 0,040 0,043 |
DSTU B V.2.7-105-2000 DSTU B V.2.7-182:2009 DSTU B V.2.7-182:2009 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
0,3 |
GOST 25898-2012 |
|
Moisture content by mass |
% |
not more than |
0,5 |
0,5 |
DSTU B V.2.7-38-95 |
|
Water absorption during partial immersion by mass |
% |
not more than |
10 |
10 |
DSTU B V.2.7-38-95 |
|
Organic matter content |
% |
not more than |
2,5 |
2,5 |
DSTU B V.2.7-38-95 |
|
Density |
kg/m3 |
– |
55±5 |
65±5 |
DSTU B V.2.7-38-95 |
|
Effective service life |
years |
not less than |
50 |
50 |
DSTU B V.2.7-182:2009 |
* – according to Protocol No. 36k/13 of the State Enterprise NDIBK
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1000, 1200 (±10) |
DSTU B V.2.7-38-95 |
|
Width |
mm |
500, 600 (±5) |
DSTU B V.2.7-38-95 |
|
Thickness (in 10 mm increments) |
mm |
50 – 200 (+5,-2) |
DSTU B V.2.7-38-95 |
|
Length, mm |
1200 |
1200 |
|
Width, mm |
600 |
600 |
|
Thickness, mm |
50 |
100 |
|
Quantity per package, slabs, pcs. |
12 |
6 |
|
Quantity per package, m2 |
8,64 |
4,32 |
|
Quantity per package, m3 |
0,432 |
0,432 |
|
Quantity per pallet, packages, pcs |
16 |
16 |
|
Quantity per pallet, m3 |
6,912 |
6,912 |
|
Loading capacity in a vehicle with a volume of 92 m3 |
76,032 |
76,032 |