TU U 23.9-32944149-013:2024
Roll roofing and waterproofing material
Product Description and Scope of Application
HYDROBASE LIGHT consists of a base made of fiberglass or polyester fabric or a combined base, coated on both sides with bituminous binder, with protective layers on top in the form of coarse-grained granules or polymer film and on the bottom in the form of polymer film. The materials are manufactured for torch-on application.
Depending on the type of protective layers and area of application, the following grades are available:
HYDROBASE LIGHT K – with coarse-grained granules on the face side and polymer film on the torch-on application side of the sheet; used for installation of the top layer of the roofing membrane;
HYDROBASE LIGHT P – with polymer film on the face and bottom sides of the sheet; used for installation of the bottom layers of the roofing membrane and waterproofing of building structures.
Transportation and Storage
Transportation is carried out by all types of transport in covered vehicles in accordance with the Cargo Transportation Rules applicable to the given type of transport. Throughout the entire storage period, the material must be protected from atmospheric precipitation. Rolls are stored vertically on pallets in a single row by height.
Packaging Information
The material is packaged in UV-stabilized film and supplied on pallets
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main characteristics
| Parameter name |
HYDROBASE LIGHT P |
HYDROBASE LIGHT K |
Test Method |
||
| Mass per unit area, kg/m²* |
2,5 |
3,5 |
EN 1849-1 |
||
| Watertightness at 2 kPa pressure for 24 hours |
– |
– |
EN 1928 |
||
| Watertightness at 60 kPa pressure for 24 hours |
No water penetration |
No water penetration |
EN 1928 |
||
| Tensile strength along / across the sheet, N, not less than for material:
on fiberglass fabric on polyester fabric |
294/- 343/- |
294/- 343/- |
DSTU B V.2.7-83 |
||
| Flexibility on a bar with a radius of (25.0±0.2) mm at temperature, °C, maximum |
0 |
0 |
DSTU B V.2.7-83 |
||
| Flow resistance at elevated temperature, °C |
≥80 |
≥80 |
EN 1110 |
||
| Loss of coarse-grained surfacing, g/sample, maximum |
– |
3 |
DSTU B V.2.7-83 |
||
| Reaction to fire | Class E | DSTU EN 13501-1 | |||
| Type of protective coating: |
|
|
|||
| top side
torch-on side |
film without logo film without logo |
slate film without logo |
|
||
| Length/width, m |
15×1 |
10×1 |
|||
| Pallet packaging |
white heat-shrink bag with logo |
||||
* – deviation from the nominal value of 1 m² mass shall not exceed ±0.25 kg
Product Description:
SWEETONDALE Pipe Section is a thermal insulation pipe section made of mineral wool based on basalt rock. Can be manufactured laminated with reinforced aluminum foil. Laminated pipe sections have a self-adhesive foil overlap, which significantly simplifies installation.
Application:
Thermal insulation of process pipelines at facilities in various industries (including food industry) and construction sector.
Maximum application temperature +650°C.
Combustibility group NG according to DSTU B V.2.7-19-95 (GOST 30244-94).
Used in civil and industrial construction for new construction, reconstruction, and insulation of pipelines for various purposes.
Can be used on round air ducts as a thermal insulation layer.
Application instructions:
According to the “Album of Technical Solutions for Equipment and Pipeline Thermal Insulation Systems” and installation instructions “Pipe Section Installation”.
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Products are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Pipe sections are packed in cardboard boxes.

Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Pipe Section 80 |
Pipe Section 120 |
Test Method |
| Density |
kg/m3 |
70-110 |
110-140 |
DSTU B V.2.7-38-95 |
| Compaction coefficient, Kc* |
– |
1-1,05 |
1-1,05 |
SNiP 2.04.14-88 |
| Thermal conductivity, λ25 |
W/m K |
0,038** |
0,037 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ125 |
W/m K |
0,048** |
0,048 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ300 |
W/m K |
0,086** |
0,087 |
DSTU B V.2.7-105-2000 |
| Tensile strength, not less than |
kPa |
15 |
20 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
0,5 |
0,5 |
DSTU B V.2.7-38-95 |
| Organic matter content |
%, not more than |
4,5 |
4,5 |
DSTU B V.2.7-38-95 |
| Combustibility class |
group |
NG |
NG |
DSTU B V.2.7-70-98 |
*- the range of diameters corresponds to standard pipe diameters;
**- according to protocol No. 60K/17.
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
| Pipe section length |
mm |
1000 (±2%) |
| Pipe diameter (internal diameter of pipe section)* |
mm |
18-324 (+5 mm; -2 mm) |
| Pipe section wall thickness |
mm |
20-100 (in increments of 10); 120 (+5 mm; -2 mm) |
TU U V.2.7.-26.8-35492904-004:2010 (Amendment No. 4)
Low-combustibility thermal and sound insulation mats
Product Description:
Lamellar mats are low-combustibility thermal and sound insulation mats formed from stone wool strips (lamellas) bonded to reinforced foil. This produces a product with increased compressive strength compared to traditional mats and less deformation during installation.
In standard configuration, the mats are covered with reinforced aluminum foil. The foil covering with sealed seams serves as a vapor barrier layer, which eliminates the need for an additional vapor barrier layer on cold pipelines and air ducts.
The base of the mats consists of non-combustible stone wool lamellas.
Application:
Thermal and vapor insulation of air ducts, ventilation equipment, tanks, as well as pipelines and flat surfaces. In civil and industrial construction, for new construction and pipeline installation, and reconstruction of buildings and structures for various purposes.
Applicable at insulated surface temperatures up to +250°C on the stone wool side (on the foil side, maximum application temperature is +80°C). Provides the following functions:
thermal insulation;
vapor barrier;
finished decorative covering for indoor installations (outdoor installations require a protective covering layer).
Application instructions:
In accordance with the “Album of Technical Solutions for Thermal Insulation Systems for Equipment and Pipelines.”
Storage:
Store in covered warehouses, preventing exposure to precipitation. During transportation, protect from damage and moisture.
Transportation:
Transportation must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging.
Main Physical and Mechanical Characteristics
| Parameter |
Unit of measurement |
Lamellar Mat 35 |
Lamellar Mat 50 |
Test Method |
| Density |
kg/m3 |
30-45 |
40-55 |
DSTU B V.2.7-38-95 |
| Compression coefficient, Kc |
– |
1 |
1 |
SNiP 2.04.14-88 |
| Thermal conductivity, λ25 |
W/mK |
0,040* |
0,040 |
DSTU B V.2.7-105-2000 |
| Thermal conductivity, λ125 |
W/mK |
0,062* |
0,062 |
DSTU B V.2.7-105-2000 |
| Compressibility under 2 kPa load, not more than |
% |
40 |
40 |
DSTU B V.2.7-38-95 |
| Resilience, not less than |
% |
– |
65 |
DSTU B V.2.7-38-95 |
| Moisture content by mass, not more than |
% |
1 |
1 |
DSTU B V.2.7-38-95 |
| Organic matter content, not more than |
% |
4,5 |
4,5 |
DSTU B V.2.7-38-95 |
*according to protocol No. 59K/17.