TU U 23.9-32944149-013:2024
Roll roofing and waterproofing material
Product Description and Scope of Application
HYDROBASE VENT is a torch-applied bitumen-polymer roofing and waterproofing roll material.
HYDROBASE VENT EKV consists of a polyester fabric base coated on both sides with bitumen-polymer binder, with protective layers on top in the form of coarse-grained granules and on the bottom in the form of fine-grained granules. An additional layer of bitumen-polymer binder is applied in strips to the lower protective layer. To prevent the material from sticking, the strips are covered with a polymer film. The material is used for installing a single-layer ventilated (“breathable”) roofing membrane.
HYDROBASE VENT EPV consists of a polyester fabric base coated on both sides with bitumen-polymer binder, with protective layers on top in the form of polyethylene film and on the bottom in the form of fine-grained granules. An additional layer of bitumen-polymer binder is applied in strips to the lower protective layer. To prevent the material from sticking, the strips are covered with a polymer film. The material is used for installing the bottom layer of a two-layer ventilated (“breathable”) roofing membrane.
Transportation and Storage
Transportation is carried out by all types of transport in covered vehicles in accordance with the Cargo Transportation Rules applicable to the given type of transport. Throughout the entire storage period, the material must be protected from atmospheric precipitation. Rolls are stored vertically on pallets in a single row by height.
Packaging Information
The material is packaged in UV-stabilized film and supplied on pallets.
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main characteristics
| Parameter name | HYDROBASE VENT EPV | HYDROBASE VENT EKV |
Test Method |
||
| Thickness, mm |
3.8 ± 0.2 |
4.2 ± 0.2 |
EN 1849-1 |
||
| Mass per unit area, kg/m²* (+0.25 kg) |
4,8 |
5,0 |
EN 1849-1 |
||
| Watertightness at 2 kPa pressure for 24 hours |
No water penetration |
EN 1928 |
|||
| Watertightness at 60 kPa pressure for 24 hours |
– |
EN 1928 |
|||
| Tensile strength, N, minimum
– longitudinal/transverse |
489/343 |
588/392 |
DSTU B V.2.7-83 |
||
| Flexibility on a bar with a radius of (25.0±0.2) mm at temperature, °C, maximum |
-20 |
-20 |
DSTU B V.2.7-83 |
||
| Flow resistance at elevated temperature, °C |
≥95 |
≥95 |
EN 1110 |
||
| Loss of coarse-grained surfacing, g/sample, maximum |
– |
1 |
DSTU B V.2.7-83 |
||
| Reaction to fire | Class E | DSTU EN 13501-1 | |||
| Type of protective coating: |
|
|
|||
| top side
torch-on side |
film ventilated covering |
slate ventilated covering |
|
||
| Length/width, m |
10×1 |
10×1 | |||
| Pallet packaging |
white heat-shrink bag with logo |
||||
*- the mass per 1 m² is provided for reference; the material is standardized by thickness. The manufacturer reserves the right to change this parameter;
TU U 23.9-32944149-013:2024
Roll roofing and waterproofing material
Product Description and Scope of Application
HYDROBASE FLEX is a torch-applied bitumen-polymer roll roofing and waterproofing material.
HYDROBASE FLEX is produced by applying a bitumen-polymer binder on both sides of a polyester base. The binder consists of bitumen, SBS polymer modifier (styrene-butadiene-styrene), and mineral filler (talc, dolomite, etc.). Coarse-grained surfacing and polymer films are used as protective layers.
Depending on the type of surfacing and application area, HYDROBASE FLEX is available in two grades:
HYDROBASE FLEX K – with coarse-grained surfacing on the top side and polymer film on the torch-applied side; used for installation of the upper layer of the roofing membrane;
HYDROBASE FLEX P – with polymer film on both sides of the sheet; used for installation of the lower layer of the roofing membrane and waterproofing of building structures (foundations, tunnels, etc.)
Transportation and Storage
Transportation is carried out by all types of transport in covered vehicles in accordance with the Cargo Transportation Rules applicable to the given type of transport. Throughout the entire storage period, the material must be protected from atmospheric precipitation. Rolls are stored vertically on pallets in a single row by height.
Packaging Information
The material is packaged in UV-stabilized film and supplied on pallets
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main characteristics
| Parameter name | HYDROBASE FLEX EPP | HYDROBASE FLEX EKP |
Test Method |
|||||
| Thickness, mm |
2.8 ± 0.2 |
3.8 ± 0.2 |
EN 1849-1 |
|||||
| Mass per unit area, kg/m²* (+0.25 kg) |
4,1 |
5,3 |
EN 1849-1 |
|||||
| Watertightness at 2 kPa pressure for 24 hours |
– |
No water penetration |
EN 1928 |
|||||
| Watertightness at 60 kPa pressure for 24 hours |
No water penetration |
– |
EN 1928 |
|||||
| Tensile strength, N, minimum
– longitudinal/transverse |
489/343 |
489/343 |
DSTU B V.2.7-83 |
|||||
| Flexibility on a bar with a radius of (25.0±0.2) mm at temperature, °C, maximum |
-20 |
-20 |
DSTU B V.2.7-83 |
|||||
| Flow resistance at elevated temperature, °C |
≥95 |
≥95 |
EN 1110 |
|||||
| Loss of coarse-grained surfacing, g/sample, maximum |
– |
1 |
DSTU B V.2.7-83 |
|||||
| Reaction to fire | Class E | DSTU EN 13501-1 | ||||||
| Type of protective coating:
upper side |
film without logo |
slate |
|
|||||
| torch-applied side |
film with logo |
film with logo |
|
|||||
| Length/width, m |
10×1 |
10×1 |
||||||
| Pallet packaging |
white heat-shrink bag with logo |
|||||||
*- the mass per 1 m² is provided for reference; the material is standardized by thickness. The manufacturer reserves the right to change this parameter;
TU U 22.2-32944149-012:2024
Thermal insulation boards made of extruded polystyrene foam
Product Description and Scope of Application
XPS CARBOLEX ECO FAS is an insulation board made of extruded polystyrene foam with a special milled surface on both sides.
Extruded polystyrene foam CARBOLEX ECO FAS
specially designed for plastered facade structures and foundation insulation.
It can also be used for other structures where enhanced adhesion requirements are imposed on insulation boards to the substrate.
Transportation and Storage
The boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from atmospheric precipitation.
Packaging Information
The boards are packaged in UV-stabilized film.
Application Instructions
According to SWEETONDALE Installation Instructions https://sweetondale.cz/docs/instruktsii/
|
Parameter |
Value |
Test Method |
| Compressive strength, kPa, minimum
30 mm 40 mm 50 mm 60 mm and above |
150 150 200 200 |
DSTU EN 826 |
| Tensile strength perpendicular to the board surface*, kPa |
100 |
DSTU EN 1607 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,033 |
DSTU EN 12939 |
| Thermal conductivity, W/m*K λA λB |
0.035 |
DSTU B V.2.7-182 |
| Water absorption during long-term immersion, not more than, % |
0,4 |
DSTU B EN 12087 |
| Flammability |
G4 |
DBN V.1.1-7 |
| Operating temperature |
from -50 °C to +75 °C |
|
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
*- tensile strength perpendicular to the face surfaces is determined for boards manufactured using the ThermoBonding method
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1180 (±10) |
DSTU EN 822 |
| Width |
mm |
580 (±8) |
DSTU EN 822 |
| Thickness*, boards with L-edge |
mm |
30, 40, 50, 100 |
DSTU EN 822 |
| Thickness tolerance class | T1 | ||
* – boards with a thickness of 60 mm and above may be manufactured using the ThermoBonding method
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL ROOF PROF 160 is a non-combustible, hydrophobized thermal and sound insulation board made of mineral wool based on basalt group rocks. Used in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures for various purposes.
THERMOWOOL ROOF PROF 160 boards are designed for use as the primary thermal insulation layer in roofing systems with reinforced concrete or metal profiled decking with roofing membranes of all types, including installations without protective screeds.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
160±15 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,039 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.042 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
60 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
DSTU EN 1607 |
| Point load, N, minimum |
600 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 |
DSTU EN 822 |
| Width |
mm |
600 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
30-130 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T5 | ||
Logistics parameters:
| Thickness, mm | 30 | 100 | |
| Quantity per package, boards, pcs | 7 |
2 |
|
| Quantity per package, m2 | 5.040 | 1.440 | |
| Quantity per package, m3 | 0.1512 |
0.144 |
|
| Quantity per pallet, packages, pcs | 44 | 48 | |
| Quantity per pallet, m3 | 6.6528 | 6.912 | |
| Loading capacity per truck, volume, 92 m3 | 73.1808 | 76.032 | |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL ROOF STANDARD 140 is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock. Used in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures for various purposes.
THERMOWOOL ROOF STANDARD 140 boards are designed for use as the primary thermal insulation layer in roofing systems on reinforced concrete or metal profiled decking with roofing membranes of all types, including installations without protective screeds.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions

Main physical and mechanical characteristics:
|
Parameter |
Value |
Test Method |
| Density, kg/m3 |
140±14 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,038 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.042 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
45 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
DSTU EN 1607 |
| Point load, N, minimum |
450 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
EN 1609 |
| Reaction to fire |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
| Length |
mm |
1200 |
DSTU EN 822 |
| Width |
mm |
600 |
DSTU EN 822 |
| Thickness (in 10 mm increments) |
mm |
40–160 |
DSTU EN 823 |
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
DSTU EN 13162 |
| Thickness tolerance class | T5 | ||
Logistics parameters:
| Thickness, mm50100 | |||
| Quantity per package, boards, pcs, | 4 |
2 |
|
| Quantity per package, m2 | 2.880 | 1.440 | |
| Quantity per package, m3 | 0.144 |
0.144 |
|
| Quantity per pallet, packages, pcs | 48 | 48 | |
| Quantity per pallet, m3 | 6.912 | 6.912 | |
| Loading capacity per truck, volume, 92m3 | 76.032 | 76.032 | |
TU U V.2.7-23.9-35492904-006:2024
Thermal and acoustic insulation boards made of mineral wool
Product Description and Scope of Application
THERMOWOOL ROOF N is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock. THERMOWOOL ROOF N boards are designed for use in civil and industrial construction as a thermal insulation layer in new construction and renovation of buildings and structures of various purposes as a lower layer in two- or three-layer roof insulation systems.
Transportation and Storage
Transportation of boards is carried out in accordance with the requirements of DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than 24 hours after storage at the warehouse. Boards must be stored packaged and stacked on pallets separately by grades and sizes. Throughout the entire storage period, the material must be protected from precipitation. The height of the board stack during storage must not exceed 3 m. Guaranteed storage period is 6 months from the date of manufacture.
Packaging Information
Polyethylene heat-shrink film is used for packaging. The wrapping method and fixation of the packaging material ensure reliable and durable packaging of the boards, protecting them during loading and unloading operations, transportation, and storage.
Application Instructions
In accordance with SWEETONDALE Installation Instructions
Main physical and mechanical characteristics:
|
Parameter |
THERMOWOOL ROOF N EXTRA 100 |
THERMOWOOL ROOF N OPTIMA 110 |
THERMOWOOL ROOF N PROF 120 |
Test Method |
| Density, kg/m3 |
100±10 |
110±10 |
120±10 |
DSTU B V.2.7-38 |
| Declared thermal conductivity at 10°C, W/(m·K), not more than |
0,036 |
0,036 |
0,036 |
DSTU B EN 12667 |
| Thermal conductivity, W/m*K λA λB |
0.039 |
0.039 |
0.041 |
DSTU B V.2.7-182 |
| Compressive stress at 10% linear deformation, kPa, not less than |
30 |
30 |
40 |
DSTU EN 826 |
| Tensile strength in the direction perpendicular to the board plane, kPa, not less than |
– |
7,5 |
7,5 |
DSTU EN 1607 |
| Point load, N, minimum |
400 |
450 |
350 |
EN 12430 |
| Long-term water absorption, kg/m2, not more than |
3 |
3 |
3 |
EN 12087 |
| Short-term water absorption, kg/m2, not more than |
1 |
1 |
1 |
EN 1609 |
| Reaction to fire |
A1 |
A1 |
A1 |
DSTU EN 13501-1 |
| Combustibility class |
NG |
NG |
NG |
DBN V.1.1-7 |
| Effective service life, years, not less than |
50 |
50 |
50 |
DSTU B V.2.7-182 |
Geometric parameters:
|
Parameter |
Unit of measurement |
THERMOWOOL ROOF N EXTRA 100 |
THERMOWOOL ROOF N OPTIMA 110 |
THERMOWOOL ROOF N PROF 120 |
Test Method |
||
| Length |
mm |
1200 |
1200 |
1200 |
DSTU EN 822 |
||
| Width |
mm |
600 |
600 |
600 |
DSTU EN 822 |
||
| Thickness (in 10 mm increments) |
mm |
50-200 |
50-200 |
50-180 |
DSTU EN 823 |
||
| Tolerance limits length / width |
mm |
±2 / ±1.5% |
±2 / ±1.5% |
±2 / ±1.5% |
DSTU EN 13162 |
||
| Thickness tolerance class | T5 | ||||||
Logistics parameters:
| Length, mm | 1200 | 1200 | 1200 | 1200 |
| Width, mm | 600 | 600 | 600 | 600 |
| Thickness, mm | 50 | 100 | 120 | 150 |
| Quantity per package, boards, pcs | 6 | 3 | 2 | 2 |
| Quantity per package, m2 | 4.32 | 2.16 | 1.44 | 1.44 |
| Quantity per package, m3 | 0.216 | 0.216 | 0.172 | 0.216 |
| Quantity per pallet, packages, pcs | 32 | 32 | 40 | 32 |
| Quantity per pallet, m3 | 6.912 | 6.912 | 6.912 | 6.912 |
| Loading capacity in truck, volume 92 m3 | 76.032 | 76.032 | 76.032 | 76.032 |
TU U V.2.7-23.9-35492904-005:2015
Non-combustible stone wool boards made from gabbro-basalt rock
Product Description:
TEKHNORUF PROF is a non-combustible, hydrophobized thermal and sound insulation board made from mineral wool based on basalt group rock.
Application:
TEKHNORUF PROF boards are designed for use in civil and industrial construction as a thermal insulation layer for repairing old roofs and as an external layer in two- or three-layer structures.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167.
Boards are shipped to the consumer no earlier than 24 hours after storage in the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material must ensure reliable and secure packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
Value |
Test Method |
|
Compressive strength under point load |
N |
not less than |
600 | DSTU B V.2.7-38 |
|
Compressive strength at 10% deformation |
MPa |
not less than |
0,06 |
DSTU B V.2.7-38 |
|
Flammability |
degree |
– |
Incombustible |
DBN V.1.1-7 |
|
Thermal conductivity: λ25 λA λb |
W/m·K |
not more than |
0,039 0,042* 0,045* |
DSTU B V.2.7-105 DSTU B V.2.7-182 DSTU B V.2.7-182 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
DSTU B V.2.7-253 |
|
Moisture content by mass |
% |
not more than |
0,5 |
DSTU B V.2.7-38 |
|
Water absorption by volume upon full immersion |
% |
not more than |
1,5 |
DSTU B V.2.7-38 |
|
Organic matter content |
% |
not more than |
4,5 |
DSTU B V.2.7-38 |
|
Density |
kg/m3 |
– |
160±15 |
DSTU B V.2.7-38 |
|
Effective service life |
years |
Not less than |
50* |
DSTU B V.2.7-182 |
* – according to Protocol No. 42-16/20 of SE NDIBMV
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1200 (±10) |
DSTU B V.2.7-38 |
|
Width |
mm |
600 (±5) |
DSTU B V.2.7-38 |
|
Thickness (in 10 mm increments) |
mm |
30 – 130 (±2) |
DSTU B V.2.7-38 |
|
Logistics Parameters |
|||
|
Thickness, mm |
30 |
100 |
|
|
Quantity per package, boards, pcs |
6 |
2
|
|
|
Quantity per package, m2 |
4,320 |
1,440 |
|
|
Quantity per package, m3 |
0,129 |
0,144
|
|
|
Quantity per pallet, packages, pcs |
52 |
48 |
|
|
Quantity per pallet, m3 |
6,739 |
6,912 |
|
|
Loading rate per vehicle, volume, 92 m3 |
74,131 |
76,032 |
|
TU U V.2.7-23.9-35492904-005:2015
Non-combustible stone wool boards made from gabbro-basalt rock
Product Description:
TECHNOROOF N is a non-combustible, hydrophobized thermal and acoustic insulation board made from mineral wool based on basalt group rocks.
Application:
In civil and industrial construction as a thermal insulation layer during new construction and renovation of buildings and structures for various purposes.
TECHNOROOF N boards are designed for use as a lower layer in a two-layer thermal insulation scheme in roofing systems with reinforced concrete or metal profiled decking. The boards are recommended for use in combination with TECHNOROOF V boards.
Storage:
The boards must be stored packaged and stacked on pallets, separated by grade and size. Throughout the entire storage period, the material must be protected from precipitation. The height of the stack during storage must not exceed 3 m.
Transportation:
Transportation of boards must be carried out in accordance with the requirements of DBN G.1-4, DSTU B V.2.7-167. Boards are shipped to the consumer no earlier than after 24-hour storage at the warehouse.
Packaging Information:
Polyethylene heat-shrink film is used for packaging. The method of wrapping and fixing the packaging material must ensure reliable and secure packaging of the boards, their protection during loading and unloading operations, transportation and storage.
Main physical and mechanical characteristics:
|
Parameter |
Unit of measurement |
Criterion |
TECHNOROOF N EXTRA |
TECHNOROOF N OPTIMA |
TECHNOROOF N PROF |
Test Method |
|
Compressive strength at 10% linear deformation |
MPa |
not less than |
0,03 |
0,035 |
0,04 |
DSTU B V.2.7-38 |
|
Compressive strength under point load |
N |
not less than |
400 |
450 |
500 |
DSTU B V.2.7-167 |
|
Flammability |
degree |
– |
Incombustible |
Incombustible |
Incombustible |
DBN V.1.1-7 |
|
Thermal conductivity: λ25 λA λB |
W/m·K |
not more than |
0,038 0,039* 0,041* |
0,038 0,039** 0,041** |
0.038 0.041 0.042 |
DSTU B V.2.7-105 DSTU B V.2.7-182 DSTU B V.2.7-182 |
|
Vapor permeability |
mg/(m·h·Pa) |
not less than |
0,3 |
0,3 |
0,3 |
DSTU B V.2.7-253 |
|
Moisture content by mass |
% |
not more than |
0,5 |
0,5 |
0,5 |
DSTU B V.2.7-38 |
|
Water absorption by volume upon full immersion |
% |
not more than |
1,5 |
1,5 |
1,5 |
DSTU B V.2.7-38 |
|
Organic matter content |
% |
not more than |
4,5 |
4,5 |
4,5 |
DSTU B V.2.7-38 |
|
Density |
kg/m3 |
– |
100±15 |
110±15 |
120±10 |
DSTU B V.2.7-38 |
|
Effective service life |
years |
Not less than |
50 |
50 |
50 |
DSTU B V.2.7-182 |
* – according to Protocol No. 41-16/20 of SE NDIBMV
** – according to Protocol No. 40K/22 of SE NDIBK
Geometric parameters:
|
Parameter |
Unit of measurement |
Value |
Test Method |
|
Length |
mm |
1200 (±10) |
DSTU B V.2.7-38 |
|
Width |
mm |
600, 1000 (±5) |
DSTU B V.2.7-38 |
|
Thickness (in 10 mm increments) |
mm |
50-200 (±2) |
DSTU B V.2.7-38 |
|
Logistics Parameters |
||||
|
Length, mm |
1200 |
1200 |
1200 |
1200 |
|
Width, mm |
600 |
600 |
600 |
600 |
|
Thickness, mm |
50 |
100 |
120 |
150 |
|
Quantity per package, boards, pcs |
6 |
3 |
2 |
2 |
|
Quantity per package, m2 |
4,32 |
2,16 |
1,44 |
1,44 |
|
Quantity per package, m3 |
0,216 |
0,216 |
0,172 |
0,216 |
|
Quantity per pallet, packages, pcs |
32 |
32 |
40 |
32 |
|
Quantity per pallet, m3 |
6,912 |
6,912 |
6,912 |
6,912 |
|
Loading capacity in a vehicle with a volume of 92 m3 |
76,032 |
76,032 |
76,032 |
76,032 |